Residential Inspection Report

1247 Maple Ridge Lane, Springfield, IL

ClientJordan Avery jordan.avery@example.com
InspectorAndrei Razumovski
DateMay 13, 2026
Property

Inspection Details

Address1247 Maple Ridge Lane, Springfield, IL
ClientJordan Avery
jordan.avery@example.com
InspectorAndrei Razumovski
DateMay 13, 2026
Time10:51 AM
Notes

Inspection Date: May 12, 2026

Time: 9:00 AM - 12:30 PM

Weather: Partly cloudy, 62ยฐF, light wind

Occupancy: Owner-occupied, owners present

Utilities: Gas, electric, and water all on at time of inspection

Limitations: Furniture prevented full access to certain wall areas in the master bedroom. Pool and spa equipment not inspected (outside scope). Roof walk-over limited to visible areas from ladder.

Reference

How to Read This Report

Every part of this property received one of the labels below. Items marked Repair or Replace or Monitor are also collected on the Summary page so you can scan them quickly. Treat the Summary as orientation, not a substitute for reading the full report โ€” context elsewhere can change how a finding affects you. Where this report recommends repair, replacement, or further evaluation, please get an estimate from a licensed contractor before closing on the property.

InspectedInspected

We visually observed this item. Unless otherwise noted in the section, it appeared to be functioning as intended at the time of the inspection, allowing for normal wear and tear.

Not InspectedNot Inspected

We did not evaluate this item. The reason is given alongside the section. Common reasons include limited access, unsafe conditions, or weather.

Not PresentNot Present

This item or system is not present at the property.

Repair or ReplaceRepair or Replace

The item is not functioning as intended, is unsafe, or has reached the end of its service life. We recommend repair or replacement by a qualified specialist.

MonitorMonitor

The item is functional today but shows an early-stage condition we want you to keep an eye on. Re-evaluate during routine maintenance, or sooner if conditions change.

Overview

Summary

3
Action
Repair or Replace
6
Watch
Monitor
1
Section

๐ŸŒณSite and Grounds

1.1 ๐Ÿ’ง Grading and Drainage

Site and Grounds > Grading and Drainage
Inspected

Lot grading slopes away from the foundation on all observable sides. Drainage appears adequate with no evidence of standing water or soil erosion at time of inspection.

1.2 ๐Ÿ›ฃ๏ธ Driveways and Walkways

Site and Grounds > Driveways and Walkways
Monitor

Concrete driveway shows minor cracking consistent with normal settling. Several expansion joint areas have minor separation. Recommend sealing cracks to prevent water infiltration and further deterioration.

1.3 ๐Ÿงฑ Retaining Walls

Site and Grounds > Retaining Walls
Not Present

No retaining walls present on this property.

2
Section

๐ŸกExterior

2.1 ๐Ÿงฑ Wall Cladding and Trim

Exterior > Wall Cladding and Trim
Inspected

Brick veneer in good condition overall. Mortar joints intact with no significant spalling or cracking. Weep holes present and clear at base course. Exterior paint on trim in good condition.

2.2 ๐Ÿšช Exterior Doors and Windows

Exterior > Exterior Doors and Windows
Inspected

Exterior doors operate smoothly and seal properly at all observed locations. Window frames and sills in good condition. Caulking intact around window perimeters with no visible gaps or deterioration.

2.3 ๐ŸŒ… Decks, Porches, and Balconies

Exterior > Decks, Porches, and Balconies
Inspected

Rear wood deck approximately 12x16 feet. Decking boards in good condition with minimal weathering. Ledger board properly flashed. Guard and handrails present and secure. Stair risers uniform height.

2.4 ๐Ÿ  Eaves, Soffits, and Fascia

Exterior > Eaves, Soffits, and Fascia
Monitor

Soffit vents present and clear. Fascia boards show minor peeling paint on north-facing elevation. Recommend repainting to prevent moisture intrusion into wood substrate.

3
Section

๐Ÿš๏ธRoofing

3.1 ๐Ÿ˜๏ธ Roof Coverings

Roofing > Roof Coverings
Repair or Replace

Asphalt shingle roof is near the end of its useful service life. Significant granular loss visible on multiple slopes. Several shingles exhibit curling and lifting at edges. Algae staining present throughout. Recommend full roof replacement by a licensed roofing contractor within 1-2 years or sooner if leaks develop.

3.2 โœจ Flashings

Roofing > Flashings
Repair or Replace

Step flashing at chimney base shows gaps and separation from the brick. Valley flashing is deteriorated with exposed substrate visible in lower valley areas. These conditions present an active leak risk and should be repaired immediately.

3.3 ๐Ÿ’ง Gutters and Downspouts

Roofing > Gutters and Downspouts
Inspected

Gutters and downspouts present on all four elevations. Gutters appear clear and in acceptable condition. Downspouts discharge away from foundation. Extensions in place at all termination points.

3.4 ๐Ÿ•ณ๏ธ Roof Penetrations

Roofing > Roof Penetrations
Inspected

Plumbing vent boots, furnace flue, and electrical mast penetrations observed from ladder. Boots and collars intact with no visible cracking or separation. Flashing around all penetrations appears serviceable.

4
Section

๐ŸชœAttic

4.1 ๐Ÿ  Roof Framing and Sheathing

Attic > Roof Framing and Sheathing
Inspected

Roof framing visible from attic access is conventional rafter construction. No evidence of sagging, broken members, or prior water damage to structural components. Ridge and hip members appear straight and intact.

4.2 ๐ŸงŠ Insulation

Attic > Insulation
Repair or Replace

Blown-in fiberglass insulation present but depth is insufficient, averaging approximately 4 inches in most areas. Current minimum recommendation is R-38 (approximately 12 inches of blown fiberglass). Recommend adding insulation to achieve current energy code minimums, which will improve heating and cooling efficiency.

4.3 ๐Ÿ’จ Ventilation

Attic > Ventilation
Inspected

Ridge vent and soffit vents provide balanced ventilation. Vapor barrier visible on attic floor. No evidence of moisture or condensation on roof deck. Ventilation appears adequate.

5
Section

๐Ÿ—๏ธStructure

5.1 ๐Ÿชจ Foundation

Structure > Foundation
Inspected

Poured concrete foundation visible at accessible locations. No significant structural cracking observed. Minor hairline cracks typical of concrete curing present, no lateral displacement or stair-step cracking noted.

5.2 ๐Ÿชต Floor Structure

Structure > Floor Structure
Inspected

Floor framing is conventional 2x10 dimensional lumber at 16 inches on center. Bridging present between joists. No evidence of moisture damage, insect activity, or compromised members in accessible areas.

6
Section

๐Ÿ•ณ๏ธBasement and Crawlspace

6.1 ๐Ÿš๏ธ Basement Conditions

Basement and Crawlspace > Basement Conditions
Not Present

No basement present. Crawlspace inspected.

6.2 ๐Ÿชœ Crawlspace Conditions

Basement and Crawlspace > Crawlspace Conditions
Inspected

Crawlspace is accessible and has adequate clearance. Vapor barrier present and in good condition, covering approximately 90% of the crawlspace floor. Ground surface dry at time of inspection. No evidence of pest activity noted.

6.3 ๐Ÿ’ฆ Moisture and Water Intrusion

Basement and Crawlspace > Moisture and Water Intrusion
Monitor

Minor efflorescence (white mineral deposits) visible on the foundation wall in the northeast corner of the crawlspace, indicating historic water seepage. Area was dry at time of inspection. Monitor during rain events; apply waterproof sealant to affected area as a preventive measure.

7
Section

โšกElectrical

7.1 ๐Ÿ”Œ Service Entrance

Electrical > Service Entrance
Inspected

200-amp service entrance. Meter base and weatherhead in good condition. Grounding electrode system visible and properly bonded. Service cable secured at appropriate intervals.

7.2 ๐ŸŽ›๏ธ Main Panel and Sub Panels

Electrical > Main Panel and Sub Panels
Inspected

200-amp Square D load center. Panel is properly secured and labeled. No double-tapped breakers observed. Wiring neatly organized. All breaker spaces filled or blanked. Adequate working clearance maintained in front of panel.

7.3 ๐Ÿ”— Branch Wiring

Electrical > Branch Wiring
Inspected

Copper branch circuit wiring throughout. Wiring in accessible areas appears in good condition with no exposed or spliced conductors outside of junction boxes. All visible junction boxes have covers.

7.4 ๐Ÿ”˜ Outlets, Switches, and Fixtures

Electrical > Outlets, Switches, and Fixtures
Inspected

Representative outlets tested throughout. All tested outlets properly grounded and wired. GFCI protection verified at bathrooms, kitchen counters, and garage. Switches operate as expected.

7.5 ๐Ÿšจ Smoke and Carbon Monoxide Alarms

Electrical > Smoke and Carbon Monoxide Alarms
Monitor

Smoke alarms present on all levels. No carbon monoxide detector observed in sleeping areas or near gas appliances. Recommend installing CO detectors per current code requirements.

8
Section

๐ŸšฐPlumbing

8.1 ๐Ÿ’ง Water Supply and Distribution

Plumbing > Water Supply and Distribution
Inspected

Copper supply lines throughout. Water pressure measured at 65 PSI, within normal range. Main shut-off valve accessible and operational in basement crawlspace. Pressure reducing valve (PRV) present and appears functional.

8.2 ๐Ÿšฝ Drain, Waste, and Vent

Plumbing > Drain, Waste, and Vent
Inspected

Drains throughout the home flow freely with no evidence of slow drains or backups. ABS drain lines visible in crawlspace. Vent stack penetrations at roof are intact. No evidence of leaks at accessible drain connections.

8.3 โ™จ๏ธ Water Heater

Plumbing > Water Heater
Inspected

50-gallon natural gas water heater, manufactured 2018 (approximately 8 years old). Unit is in good working condition. Temperature/pressure relief valve present with drain line properly terminated. Combustion air supply adequate. Seismic strapping installed.

8.4 ๐Ÿšฟ Fixtures and Faucets

Plumbing > Fixtures and Faucets
Inspected

All plumbing fixtures operate properly. Faucets and valves functional with no observed leaks. Hot and cold water confirmed at all tested locations. Shut-off valves present under sinks and toilets.

8.5 ๐Ÿช” Fuel Supply

Plumbing > Fuel Supply
Inspected

Natural gas supply. Gas meter accessible. Flexible gas connectors on appliances appear in good condition. No gas odors detected during inspection. Main gas shut-off accessible.

9
Section

โ„๏ธHVAC

9.1 ๐Ÿ”ฅ Heating Equipment

HVAC > Heating Equipment
Inspected

80% efficient natural gas forced-air furnace, manufactured 2016 (approximately 10 years old). Unit operates properly through normal thermostat cycle. Heat exchanger appears intact. Flame color normal. Filter was recently replaced (noted by owner).

9.2 ๐ŸงŠ Cooling Equipment

HVAC > Cooling Equipment
Inspected

Central air conditioning, 3-ton unit, manufactured 2018. Unit cycles on and off properly. Adequate supply of cool air confirmed at registers. Refrigerant lines insulated and undamaged. Condenser coils clean.

9.3 ๐ŸŒฌ๏ธ Distribution, Filters, and Thermostats

HVAC > Distribution, Filters, and Thermostats
Inspected

Supply and return air registers present in all rooms. Airflow adequate at all observed registers. Ductwork in crawlspace properly supported and insulated. No disconnected or damaged ducts observed.

9.4 ๐Ÿ’จ Venting and Combustion Air

HVAC > Venting and Combustion Air
Inspected

B-vent flue from furnace and water heater in good condition. No gaps, rust, or improper connections observed. Flue terminates above roofline. Combustion air supply adequate for appliances.

9.5 ๐Ÿ’ง Condensate

HVAC > Condensate
Inspected

Condensate drain line from air handler terminates properly. Secondary drain pan present under air handler. No evidence of prior overflow or water damage beneath unit.

10
Section

๐Ÿ›‹๏ธInterior

10.1 ๐Ÿงฑ Walls, Ceilings, and Floors

Interior > Walls, Ceilings, and Floors
Inspected

Interior finishes in good condition throughout. No evidence of significant moisture intrusion, staining, or active leaks on ceilings. Minor cosmetic nail pops and hairline cracks noted in drywall - typical for the age of the home. Hardwood floors in main living areas in good condition.

10.2 ๐Ÿšช Interior Doors and Windows

Interior > Interior Doors and Windows
Inspected

Interior doors operate smoothly and latch properly. Window sashes move freely and lock securely. Insulated glass units appear intact with no visible fogging or seal failure observed.

10.3 ๐Ÿชœ Stairs and Railings

Interior > Stairs and Railings
Monitor

Main staircase is structurally sound. Handrail on the right side is loose at the top newel post and does not meet the graspability requirement. Recommend securing handrail and verifying adequate attachment to wall stringers.

11
Section

๐ŸณKitchen

11.1 ๐Ÿ—„๏ธ Cabinets and Countertops

Kitchen > Cabinets and Countertops
Inspected

Kitchen cabinets in good condition. Doors and drawers operate properly. Countertops are solid surface with no significant damage. Under-sink cabinet base shows no evidence of water damage.

11.2 ๐Ÿšฐ Sink and Plumbing

Kitchen > Sink and Plumbing
Inspected

Kitchen sink with pull-out spray faucet operates properly. Dishwasher drain loop present and properly installed. Garbage disposal functional. No leaks observed under sink.

11.3 ๐Ÿฝ๏ธ Appliances

Kitchen > Appliances
Inspected

Built-in microwave, range, and dishwasher present. All operate through normal test cycle. Range burners all ignite. Oven reaches temperature. Dishwasher completes wash cycle. Range hood fan and light functional.

12
Section

๐Ÿ›๏ธBedrooms

12.1 ๐Ÿ›๏ธ Bedroom #1

Bedrooms > Bedroom #1
Inspected

Master bedroom in good condition. Adequate natural light from two double-hung windows. Hardwood flooring intact with no significant gaps or damage. Closet present with standard bi-fold doors. Overhead light fixture with functional switch. No evidence of moisture, staining, or pest activity at walls or ceiling.

12.2 ๐Ÿ›๏ธ Bedroom #2

Bedrooms > Bedroom #2
Inspected

Second bedroom in satisfactory condition. Single double-hung window with functional sash and latch. Carpet in average condition with minor wear at threshold. Closet present. Overhead light fixture operational.

12.3 ๐Ÿ›๏ธ Bedroom #3

Bedrooms > Bedroom #3
Monitor

Third bedroom functional. Window sash operational but the rough opening width measures approximately 18 inches, which falls below the 20-inch minimum egress width required by current residential codes for sleeping rooms. Recommend evaluation by a licensed contractor to determine if window replacement or enlargement is warranted for life-safety compliance.

13
Section

๐Ÿ›Bathrooms

13.1 ๐Ÿ› Bathroom #1

Bathrooms > Bathroom #1
Inspected

Master bathroom in good condition. Shower enclosure with tile surround, grout intact with no cracking or missing sections. Exhaust fan present and operational. GFCI-protected outlets. No evidence of moisture or water damage at walls or floor.

13.2 ๐Ÿ› Bathroom #2

Bathrooms > Bathroom #2
Inspected

Hall bathroom in good condition. Tub/shower with fiberglass surround, intact with no cracks. Exhaust fan present and operational. GFCI outlets in place.

13.3 ๐Ÿ› Bathroom #3

Bathrooms > Bathroom #3
Not Present

Third bathroom not present in this property.

14
Section

๐ŸงบLaundry

14.1 ๐Ÿ”— Hookups and Connections

Laundry > Hookups and Connections
Inspected

120/240V electrical outlet and hot/cold water valves present for washer and dryer. Hookups functional. Drain standpipe properly sized and secured. Washer pan present.

14.2 ๐Ÿ’จ Dryer Venting

Laundry > Dryer Venting
Inspected

Dryer vents through rigid metal duct to exterior. Duct length is within acceptable limits. Exterior termination cap present with damper. Duct appeared clean.

15
Section

๐Ÿ”ฅFireplace and Chimney

15.1 ๐Ÿ”ฅ Fireplace or Stove

Fireplace and Chimney > Fireplace or Stove
Not Present

No fireplace present in this property.

15.2 ๐Ÿญ Chimney and Flue

Fireplace and Chimney > Chimney and Flue
Not Present

No chimney or flue present in this property.

16
Section

๐Ÿš—Garage

16.1 ๐Ÿšช Vehicle Doors

Garage > Vehicle Doors
Inspected

Two-car attached garage with two sectional doors. Both doors operate properly on tracks with no binding or obstruction. Springs balanced. Door hardware in good condition.

16.2 ๐ŸŽš๏ธ Door Openers

Garage > Door Openers
Inspected

Garage door openers present on both doors. Auto-reverse safety feature verified. Wall controls and remotes functional. Safety sensors present and aligned.

16.3 ๐Ÿ›ก๏ธ Fire Separation

Garage > Fire Separation
Inspected

Garage-to-living-space door is solid-core with self-closing hinges. Door seals properly. No penetrations observed in common wall between garage and living space.